PFOA/PFOS average above EPA limit

PFAS in 78664 tap water

ZIP 78664 (Round Rock, TX, Williamson County) is served by 4 public water systems that EPA tested for 29 PFAS and lithium.

City of Round Rock

Serves about 130,662 people · Surface water · Sampled 2024-10 to 2025-07 · 10 samples at 3 locations · PWS ID TX2460003

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid2.5avg6.7max2,000 pptEPA health-based value (Hazard Index)Detected, below level2 of 10 samples
PFBAPerfluorobutanoic acid2.5avg5.1max7,000 pptUSGS health-based screening levelDetected, below level1 of 10 samples
PFHxAPerfluorohexanoic acid1.9avg3.7max4,000 pptUSGS health-based screening levelDetected, below level1 of 10 samples
PFPeAPerfluoropentanoic acid3.4avg6.7maxNo federal levelDetected (no federal level)2 of 10 samples
lithiumLithium8.4avg13.5max10 µg/LEPA health reference levelOne or more samples above6 of 10 samples

25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for City of Round Rock →

Manville WSC

Serves about 39,648 people · Purchased surface water · Sampled 2023-02 to 2023-11 · 20 samples at 9 locations · PWS ID TX2270033

PFOA/PFOS average above EPA limit

ChemicalAverage*HighestLevelStatus
PFOAPerfluorooctanoic acid3avg5.9max4 pptEPA limit (MCL)One or more samples above1 of 20 samples
PFOSPerfluorooctanesulfonic acid11avg12.4max4 pptEPA limit (MCL)Average above EPA limit7 of 20 samples
PFHxSPerfluorohexanesulfonic acid6.8avg7max10 pptEPA 2024 limit, proposed for repealDetected, below level7 of 20 samples
PFNAPerfluorononanoic acid16.6avg24.3max10 pptEPA 2024 limit, proposed for repealAverage above 2024 limit3 of 20 samples
PFBSPerfluorobutanesulfonic acid9.6avg10max2,000 pptEPA health-based value (Hazard Index)Detected, below level8 of 20 samples
PFBAPerfluorobutanoic acid6.5avg7.4max7,000 pptUSGS health-based screening levelDetected, below level3 of 20 samples
PFHxAPerfluorohexanoic acid6.5avg8.7max4,000 pptUSGS health-based screening levelDetected, below level4 of 20 samples
PFPeAPerfluoropentanoic acid7.5avg9.1maxNo federal levelDetected (no federal level)7 of 20 samples
PFHpAPerfluoroheptanoic acid2.1avg4.3maxNo federal levelDetected (no federal level)1 of 20 samples
PFUnAPerfluoroundecanoic acid1.4avg2.7maxNo federal levelDetected (no federal level)1 of 20 samples
lithiumLithium71.3avg83.8max10 µg/LEPA health reference levelAbove screening level17 of 20 samples

19 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (5)
  • 2025-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .092 MG/L Resolved
  • 2025-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .094 MG/L Resolved
  • 2025-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .09 MG/L Resolved
  • 2025-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
  • 2020-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
Full report for Manville WSC →

Jonah Water SUD

Serves about 29,861 people · Purchased surface water · Sampled 2023-05 to 2024-03 · 19 samples at 6 locations · PWS ID TX2460022

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFOAPerfluorooctanoic acid1.3avg5.1max4 pptEPA limit (MCL)One or more samples above1 of 16 samples
PFOSPerfluorooctanesulfonic acid2.9avg5.7max4 pptEPA limit (MCL)One or more samples above2 of 16 samples
PFHxSPerfluorohexanesulfonic acid4.5avg5.6max10 pptEPA 2024 limit, proposed for repealDetected, below level3 of 16 samples
PFBSPerfluorobutanesulfonic acid8.9avg9.3max2,000 pptEPA health-based value (Hazard Index)Detected, below level6 of 16 samples
PFBAPerfluorobutanoic acid7avg15.8max7,000 pptUSGS health-based screening levelDetected, below level4 of 16 samples
PFHxAPerfluorohexanoic acid6avg9.2max4,000 pptUSGS health-based screening levelDetected, below level6 of 16 samples
PFPeAPerfluoropentanoic acid11.4avg21.2maxNo federal levelDetected (no federal level)6 of 16 samples
lithiumLithium36.5avg38.6max10 µg/LEPA health reference levelAbove screening level9 of 16 samples

22 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (2)
  • 2019-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
  • 2018-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .084 MG/L Resolved
Full report for Jonah Water SUD →

Windermere Community

Serves about 21,231 people · Purchased surface water · Sampled 2024-09 to 2025-05 · 16 samples at 6 locations · PWS ID TX2270161

PFOA/PFOS average above EPA limit

ChemicalAverage*HighestLevelStatus
PFOSPerfluorooctanesulfonic acid7.3avg7.5max4 pptEPA limit (MCL)Average above EPA limit6 of 10 samples
PFHxSPerfluorohexanesulfonic acid6.3avg6.5max10 pptEPA 2024 limit, proposed for repealDetected, below level8 of 10 samples
PFBSPerfluorobutanesulfonic acid8.7avg9.2max2,000 pptEPA health-based value (Hazard Index)Detected, below level8 of 10 samples
PFBAPerfluorobutanoic acid5.5avg5.7max7,000 pptUSGS health-based screening levelDetected, below level4 of 10 samples
PFHxAPerfluorohexanoic acid3.6avg3.9max4,000 pptUSGS health-based screening levelDetected, below level4 of 10 samples
PFPeAPerfluoropentanoic acid5.5avg5.9maxNo federal levelDetected (no federal level)8 of 10 samples
lithiumLithium32.3avg33.7max10 µg/LEPA health reference levelAbove screening level7 of 11 samples

23 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Windermere Community →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Other ZIP codes on the same water

76511 76530 76537 76574 76578 77388 78615 78621 78626 78634 78653 78660 78665 78680 78681 78682 78683 78691 78708 78709 78714 78723 78724 78725 78728 78731 78746 78750 78753 78755 78758 78767 78768

On a private well? EPA's data covers public water systems only. Your state health department can tell you how to test a well.