A sample above an EPA limit

PFAS in 78640 tap water

ZIP 78640 (Uhland, TX, Hays County) is served by 4 public water systems that EPA tested for 29 PFAS and lithium.

City of Kyle

Serves about 52,000 people · Purchased surface water · Sampled 2023-08 to 2024-05 · 10 samples at 4 locations · PWS ID TX1050002

3 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid9.1avg19.4max7,000 pptUSGS health-based screening levelDetected, below level3 of 10 samples
PFHxAPerfluorohexanoic acid1.6avg3.1max4,000 pptUSGS health-based screening levelDetected, below level2 of 10 samples
PFPeAPerfluoropentanoic acid3.9avg4.5maxNo federal levelDetected (no federal level)5 of 10 samples
lithiumLithium10.9avg12.6max10 µg/LEPA health reference levelAbove screening level2 of 10 samples

26 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (1)
  • 2016-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .087 MG/L Resolved
Full report for City of Kyle →

Goforth SUD

Serves about 34,893 people · Purchased surface water · Sampled 2023-04 to 2024-07 · 13 samples at 4 locations · PWS ID TX1050019

5 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid3.6avg7.2max2,000 pptEPA health-based value (Hazard Index)Detected, below level2 of 12 samples
PFBAPerfluorobutanoic acid1.6avg6.2max7,000 pptUSGS health-based screening levelDetected, below level2 of 12 samples
PFHxAPerfluorohexanoic acid1avg4.1max4,000 pptUSGS health-based screening levelDetected, below level1 of 12 samples
PFPeAPerfluoropentanoic acid4.2avg5.1maxNo federal levelDetected (no federal level)7 of 12 samples
6:2 FTS6:2 Fluorotelomer sulfonic acid7.8avg15.6maxNo federal levelDetected (no federal level)1 of 12 samples
lithiumLithium13.6avg14.2max10 µg/LEPA health reference levelAbove screening level2 of 12 samples

24 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (2)
  • 2024-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .085 MG/L Resolved
  • 2024-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .087 MG/L Resolved
Full report for Goforth SUD →

County Line SUD

Serves about 19,609 people · Purchased surface water · Sampled 2025-03 to 2025-12 · 6 samples at 2 locations · PWS ID TX1050038

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFPeAPerfluoropentanoic acid1.9avg4.5maxNo federal levelDetected (no federal level)2 of 6 samples
lithiumLithium6avg11.9max10 µg/LEPA health reference levelOne or more samples above2 of 6 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for County Line SUD →

Plum Creek

Serves about 7,065 people · Purchased surface water · Sampled 2024-03 to 2025-02 · 10 samples at 2 locations · PWS ID TX1050028

No PFAS detected

ChemicalAverage*HighestLevelStatus
lithiumLithium13.3avg19.1max10 µg/LEPA health reference levelAbove screening level5 of 8 samples

29 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Plum Creek →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Other ZIP codes on the same water

78610 78644 78656