1 PFAS detected, below EPA limits

PFAS in 66083 tap water

ZIP 66083 (Spring Hill, KS, Miami County) is served by 5 public water systems that EPA tested for 29 PFAS and lithium.

Water District 1 of Johnson Co

Serves about 490,000 people · Surface water · Sampled 2024-04 to 2026-02 · 12 samples at 3 locations · PWS ID KS2009110

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid2.6avg5.3max7,000 pptUSGS health-based screening levelDetected, below level2 of 12 samples
lithiumLithium41.3avg50.9max10 µg/LEPA health reference levelAbove screening level11 of 12 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Water District 1 of Johnson Co →

Gardner, City Of

Serves about 23,942 people · Surface water · Sampled 2023-06 to 2024-03 · 12 samples at 1 location · PWS ID KS2009106

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFPeAPerfluoropentanoic acid1.7avg3.4maxNo federal levelDetected (no federal level)2 of 4 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Gardner, City Of →

Miami Co RWD 2

Serves about 10,311 people · Surface water · Sampled 2025-02 to 2025-11 · 4 samples at 1 location · PWS ID KS2012101

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid2.1avg8.4max7,000 pptUSGS health-based screening levelDetected, below level1 of 4 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (2)
  • 2021-01-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Resolved
  • 2016-03-01 Coliform (TCR) Total Coliform Rule Resolved
Full report for Miami Co RWD 2 →

Johnson Co RWD 7

Serves about 6,457 people · Purchased surface water · Sampled 2025-02 to 2025-11 · 15 samples at 3 locations · PWS ID KS2009104

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid1.8avg7.1max7,000 pptUSGS health-based screening levelDetected, below level1 of 12 samples
lithiumLithium38.4avg41.1max10 µg/LEPA health reference levelAbove screening level8 of 12 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Johnson Co RWD 7 →

Spring Hill, City Of

Serves about 5,694 people · Purchased surface water · Sampled 2024-02 to 2024-12 · 9 samples at 1 location · PWS ID KS2009120

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid3avg6.9max7,000 pptUSGS health-based screening levelDetected, below level2 of 4 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Spring Hill, City Of →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Other ZIP codes on the same water

66013 66018 66021 66025 66030 66031 66040 66053 66061 66062 66064 66071 66079 66085 66092 66202 66203 66204 66205 66206 66207 66208 66209 66210 66211 66212 66213 66214 66215 66216 66217 66218 66219 66220 66221 66223 66224 66226 66227

Questions

Is 66083 tap water safe to drink?

PFAS were detected (PFBA) in the Water District 1 of Johnson Co water system, but averages were below EPA's limits. EPA SDWIS lists 2 health-based violations since 2016 for these systems; see each system below. This is monitoring data, not a safety ruling. Your utility's annual Consumer Confidence Report has the full picture.

What filter removes PFAS in 66083?

Pick one whose NSF/ANSI 53 or 58 certification names PFOA and PFOS, from NSF, IAPMO R&T, WQA, CSA or UL. Certified pitchers start around $35; under-sink carbon and reverse osmosis systems cost $150 to $700. Reverse osmosis also handles shorter-chain PFAS better. See best water filters for PFAS.

More for ZIP 66083 (Spring Hill)

On a private well? EPA's data covers public water systems only. Your state health department can tell you how to test a well.