A sample above an EPA limit

PFAS in 37764 tap water

ZIP 37764 (Sevierville, TN, Sevier County) is served by 3 public water systems that EPA tested for 29 PFAS and lithium.

Knoxville Utilities Board-Kub

Serves about 254,671 people · Surface water · Sampled 2024-01 to 2024-10 · 4 samples at 1 location · PWS ID TN0000366

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid0.9avg3.7max2,000 pptEPA health-based value (Hazard Index)Detected, below level1 of 4 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Knoxville Utilities Board-Kub →

Sevierville Water System

Serves about 39,885 people · Surface water · Sampled 2023-09 to 2024-07 · 6 samples at 1 location · PWS ID TN0000617

No PFAS detected

None of the 29 PFAS EPA tested for were found at or above reporting levels and lithium was not detected.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Sevierville Water System →

Shady Grove Utility District

Serves about 27,672 people · Purchased surface water · Sampled 2023-07 to 2024-07 · 14 samples at 2 locations · PWS ID TN0000626

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFOSPerfluorooctanesulfonic acid1.1avg4.2max4 pptEPA limit (MCL)One or more samples above1 of 8 samples
PFPeAPerfluoropentanoic acid2avg4.7maxNo federal levelDetected (no federal level)2 of 8 samples

27 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Shady Grove Utility District →

Filters certified for what was found

Here, PFAS were detected. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Other ZIP codes on the same water

37725 37760 37820 37862 37865 37871 37876 37902 37909 37912 37914 37915 37916 37917 37918 37919 37920 37921 37922 37923 37924 37931

Questions

Is 37764 tap water safe to drink?

No water system serving ZIP 37764 averaged above the PFOA/PFOS limit, but Shady Grove Utility District had a sample above an epa limit (sample or limit details are in the table below). EPA SDWIS lists no health-based violations since 2016 for these systems. This is monitoring data, not a safety ruling. Your utility's annual Consumer Confidence Report has the full picture.

What filter removes PFAS in 37764?

Pick one whose NSF/ANSI 53 or 58 certification names PFOA and PFOS, from NSF, IAPMO R&T, WQA, CSA or UL. Certified pitchers start around $35; under-sink carbon and reverse osmosis systems cost $150 to $700. Reverse osmosis also handles shorter-chain PFAS better. See best water filters for PFAS.

More for ZIP 37764 (Sevierville)

On a private well? EPA's data covers public water systems only. Your state health department can tell you how to test a well.