PFOA/PFOS average above EPA limit
Pewaukee City Water and Sewer Utility: PFAS in the water
Serves about 8,671 people · Groundwater · Sampled 2024-06 to 2024-12 · 16 samples at 8 locations. Public water system WI2680214, Wisconsin.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 4.2avg | 8.5max | 4 pptEPA limit (MCL) | Average above EPA limit3 of 16 samples |
| PFOSPerfluorooctanesulfonic acid | 6avg | 12max | 4 pptEPA limit (MCL) | Average above EPA limit4 of 16 samples |
| PFHxSPerfluorohexanesulfonic acid | 34.5avg | 69max | 10 pptEPA 2024 limit, proposed for repeal | Average above 2024 limit6 of 16 samples |
| PFBSPerfluorobutanesulfonic acid | 13.5avg | 27max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level4 of 16 samples |
| PFBAPerfluorobutanoic acid | 6.5avg | 13max | 7,000 pptUSGS health-based screening level | Detected, below level2 of 16 samples |
| PFHxAPerfluorohexanoic acid | 20avg | 40max | 4,000 pptUSGS health-based screening level | Detected, below level5 of 16 samples |
| PFPeAPerfluoropentanoic acid | 12avg | 24max | No federal level | Detected (no federal level)6 of 16 samples |
| PFHpAPerfluoroheptanoic acid | 4avg | 8max | No federal level | Detected (no federal level)3 of 16 samples |
| PFPeSPerfluoropentanesulfonic acid | 10.5avg | 21max | No federal level | Detected (no federal level)4 of 16 samples |
| 6:2 FTS6:2 Fluorotelomer sulfonic acid | 17.5avg | 35max | No federal level | Detected (no federal level)4 of 16 samples |
| lithiumLithium | 10.5avg | 11max | 10 µg/LEPA health reference level | Above screening level4 of 16 samples |
19 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 3.46 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, radium/radionuclide violations are on record, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2026-04-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 19.5 PCI/L Archived
- 2026-01-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 16.95 PCI/L Archived
- 2025-10-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 20.03 PCI/L Archived
- 2025-07-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 21.65 PCI/L Archived
- 2025-04-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 24.45 PCI/L Archived
- 2025-01-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 26.95 PCI/L Archived
- 2024-10-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 24.8 PCI/L Archived
- 2024-07-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 23.2 PCI/L Archived
- 2024-04-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 21.1 PCI/L Archived
- 2024-01-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 17.45 PCI/L Archived
- 2023-10-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 17.43 PCI/L Archived
- 2019-07-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 5.75325 PCI/L Archived
- 2018-04-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 5.61 PCI/L Resolved
- 2018-01-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 6.2 PCI/L Resolved
- 2017-10-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 6.2 PCI/L Resolved
- 2017-07-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 6.48 PCI/L Resolved
- 2017-04-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 5.94 PCI/L Resolved
- 2017-01-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 5.57 PCI/L Resolved