PFOA/PFOS average above EPA limit
New Baltimore Regional: PFAS in the water
Serves about 8,818 people · Groundwater · Sampled 2023-06 to 2023-12 · 20 samples at 9 locations. Public water system VA6061318, Virginia.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 2.5avg | 4.9max | 4 pptEPA limit (MCL) | One or more samples above2 of 18 samples |
| PFOSPerfluorooctanesulfonic acid | 11.8avg | 12max | 4 pptEPA limit (MCL) | Average above EPA limit4 of 18 samples |
| PFHxSPerfluorohexanesulfonic acid | 5.6avg | 6.2max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level3 of 18 samples |
| PFBSPerfluorobutanesulfonic acid | 5.4avg | 5.6max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level5 of 18 samples |
| PFHxAPerfluorohexanoic acid | 6.8avg | 8.2max | 4,000 pptUSGS health-based screening level | Detected, below level12 of 18 samples |
| PFPeAPerfluoropentanoic acid | 9.8avg | 11max | No federal level | Detected (no federal level)10 of 18 samples |
| lithiumLithium | 30.4avg | 34.8max | 10 µg/LEPA health reference level | Above screening level2 of 18 samples |
23 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.56 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, radium/radionuclide violations are on record, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2017-04-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 7 PCI/L Resolved