1 PFAS detected, below EPA limits
Diana SUD: PFAS in the water
Serves about 7,953 people · Purchased surface water · Sampled 2025-04 to 2025-12 · 27 samples at 5 locations. Public water system TX2300006, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFBAPerfluorobutanoic acid | 7.7avg | 11max | 7,000 pptUSGS health-based screening level | Detected, below level5 of 17 samples |
| lithiumLithium | 14.5avg | 18max | 10 µg/LEPA health reference level | Above screening level9 of 20 samples |
28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
No health-based violations recorded in EPA SDWIS since 2016.