5 PFAS detected, below EPA limits
City of San Angelo: PFAS in the water
Serves about 105,229 people · Surface water · Sampled 2023-04 to 2024-01 · 4 samples at 1 location. Public water system TX2260001, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFHxSPerfluorohexanesulfonic acid | 8.7avg | 9.7max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level4 of 4 samples |
| PFBSPerfluorobutanesulfonic acid | 7.4avg | 8.4max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level4 of 4 samples |
| PFBAPerfluorobutanoic acid | 7.8avg | 10.2max | 7,000 pptUSGS health-based screening level | Detected, below level4 of 4 samples |
| PFHxAPerfluorohexanoic acid | 1avg | 4max | 4,000 pptUSGS health-based screening level | Detected, below level1 of 4 samples |
| PFPeAPerfluoropentanoic acid | 0.8avg | 3max | No federal level | Detected (no federal level)1 of 4 samples |
| lithiumLithium | 47avg | 50.1max | 10 µg/LEPA health reference level | Above screening level4 of 4 samples |
24 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.87 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2024-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .086 MG/L Resolved
- 2024-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .083 MG/L Resolved