5 PFAS detected, below EPA limits
G M WSC: PFAS in the water
Serves about 12,672 people · Surface water · Sampled 2023-01 to 2024-02 · 20 samples at 5 locations. Public water system TX2020067, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFBSPerfluorobutanesulfonic acid | 4.8avg | 15.1max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level2 of 18 samples |
| PFBAPerfluorobutanoic acid | 1.7avg | 6.9max | 7,000 pptUSGS health-based screening level | Detected, below level1 of 18 samples |
| PFHxAPerfluorohexanoic acid | 1.5avg | 6max | 4,000 pptUSGS health-based screening level | Detected, below level1 of 18 samples |
| PFPeAPerfluoropentanoic acid | 1.6avg | 6.3max | No federal level | Detected (no federal level)1 of 18 samples |
| NFDHANonafluoro-3,6-dioxaheptanoic acid | 9.8avg | 39max | No federal level | Detected (no federal level)1 of 18 samples |
| lithiumLithium | 10.8avg | 11.2max | 10 µg/LEPA health reference level | Above screening level7 of 18 samples |
24 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2024-10-17 LEAD AND COPPER RULE REVISIONS Lead and Copper Rule Revisions Resolved
- 2024-03-09 Revised Total Coliform Rule Revised Total Coliform Rule Resolved
- 2021-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .084 MG/L Resolved
- 2017-07-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Resolved
- 2016-09-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Resolved
- 2016-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .088 MG/L Resolved
- 2016-01-01 Total Haloacetic Acids (HAA5) Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .09 MG/L Resolved
- 2016-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
- 2016-01-01 Total Haloacetic Acids (HAA5) Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .065 MG/L Resolved