PFOA/PFOS average above EPA limit
Hawley WSC: PFAS in the water
Serves about 8,436 people · Purchased surface water · Sampled 2024-01 to 2024-10 · 16 samples at 4 locations. Public water system TX1270006, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 5.2avg | 8.8max | 4 pptEPA limit (MCL) | Average above EPA limit9 of 16 samples |
| PFOSPerfluorooctanesulfonic acid | 20.9avg | 32.3max | 4 pptEPA limit (MCL) | Average above EPA limit12 of 16 samples |
| PFHxSPerfluorohexanesulfonic acid | 23avg | 36.4max | 10 pptEPA 2024 limit, proposed for repeal | Average above 2024 limit12 of 16 samples |
| PFBSPerfluorobutanesulfonic acid | 6.2avg | 9.5max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level12 of 16 samples |
| PFBAPerfluorobutanoic acid | 15.6avg | 21.8max | 7,000 pptUSGS health-based screening level | Detected, below level14 of 16 samples |
| PFHxAPerfluorohexanoic acid | 18.4avg | 27.1max | 4,000 pptUSGS health-based screening level | Detected, below level12 of 16 samples |
| PFPeAPerfluoropentanoic acid | 13.9avg | 22.7max | No federal level | Detected (no federal level)12 of 16 samples |
| PFHpAPerfluoroheptanoic acid | 7.8avg | 11.9max | No federal level | Detected (no federal level)12 of 16 samples |
| PFPeSPerfluoropentanesulfonic acid | 1.2avg | 5max | No federal level | Detected (no federal level)3 of 16 samples |
| lithiumLithium | 12.9avg | 13.4max | 10 µg/LEPA health reference level | Above screening level16 of 16 samples |
20 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 2.31 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
No health-based violations recorded in EPA SDWIS since 2016.