4 PFAS detected, below EPA limits
Parkway Utility District: PFAS in the water
Serves about 7,323 people · Groundwater · Sampled 2023-03 to 2024-03 · 12 samples at 2 locations. Public water system TX1010750, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFBSPerfluorobutanesulfonic acid | 0.8avg | 3.1max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level1 of 8 samples |
| PFBAPerfluorobutanoic acid | 5.5avg | 7.6max | 7,000 pptUSGS health-based screening level | Detected, below level3 of 8 samples |
| PFHxAPerfluorohexanoic acid | 3.8avg | 6max | 4,000 pptUSGS health-based screening level | Detected, below level3 of 8 samples |
| PFPeAPerfluoropentanoic acid | 4.5avg | 6.7max | No federal level | Detected (no federal level)3 of 8 samples |
| lithiumLithium | 17avg | 19max | 10 µg/LEPA health reference level | Above screening level4 of 8 samples |
25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2018-04-01 Total Haloacetic Acids (HAA5) Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .062 MG/L Resolved