A sample above an EPA limit
Springs Hill WSC: PFAS in the water
Serves about 35,541 people · Surface water · Sampled 2023-06 to 2024-03 · 10 samples at 3 locations. Public water system TX0940022, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOSPerfluorooctanesulfonic acid | 1.1avg | 4.4max | 4 pptEPA limit (MCL) | One or more samples above1 of 10 samples |
| PFBAPerfluorobutanoic acid | 2.7avg | 5.4max | 7,000 pptUSGS health-based screening level | Detected, below level1 of 10 samples |
| PFPeAPerfluoropentanoic acid | 1.6avg | 3.5max | No federal level | Detected (no federal level)2 of 10 samples |
| lithiumLithium | 17.1avg | 36.3max | 10 µg/LEPA health reference level | Above screening level5 of 10 samples |
26 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Filters certified for what was found
Here, PFAS were detected, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2024-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .082 MG/L Resolved
- 2024-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .084 MG/L Resolved
- 2019-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .082 MG/L Resolved
- 2019-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .082 MG/L Resolved
- 2019-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .095 MG/L Resolved
- 2019-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .088 MG/L Resolved
- 2019-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .094 MG/L Resolved
- 2017-07-28 Revised Total Coliform Rule Revised Total Coliform Rule Resolved