PFOA/PFOS average above EPA limit
Town of Anthony: PFAS in the water
Serves about 5,555 people · Groundwater · Sampled 2023-01 to 2023-10 · 9 samples at 3 locations. Public water system TX0710001, Texas.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 14.6avg | 29.1max | 4 pptEPA limit (MCL) | Average above EPA limit1 of 6 samples |
| PFOSPerfluorooctanesulfonic acid | 16.6avg | 33.1max | 4 pptEPA limit (MCL) | Average above EPA limit1 of 6 samples |
| PFHxSPerfluorohexanesulfonic acid | 2.9avg | 5.7max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level1 of 6 samples |
| PFBSPerfluorobutanesulfonic acid | 14.3avg | 28.7max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level1 of 6 samples |
| PFHxAPerfluorohexanoic acid | 3.6avg | 7.3max | 4,000 pptUSGS health-based screening level | Detected, below level1 of 6 samples |
| PFPeAPerfluoropentanoic acid | 4avg | 8.1max | No federal level | Detected (no federal level)1 of 6 samples |
| PFHpAPerfluoroheptanoic acid | 3.1avg | 6.2max | No federal level | Detected (no federal level)1 of 6 samples |
| lithiumLithium | 156avg | 170max | 10 µg/LEPA health reference level | Above screening level6 of 6 samples |
22 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.29 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, arsenic violations are on record, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2025-07-01 Arsenic Arsenic Rule · measured .012 MG/L Resolved
- 2025-04-01 Arsenic Arsenic Rule · measured .011 MG/L Resolved
- 2025-01-01 Arsenic Arsenic Rule · measured .011 MG/L Resolved
- 2024-10-17 LEAD AND COPPER RULE REVISIONS Lead and Copper Rule Revisions Resolved
- 2020-04-01 Arsenic Arsenic Rule · measured .011 MG/L Resolved
- 2020-01-01 Arsenic Arsenic Rule · measured .011 MG/L Resolved
- 2019-10-01 Arsenic Arsenic Rule · measured .011 MG/L Resolved