3 PFAS detected, below EPA limits

Ector County Utility District: PFAS in the water

Serves about 15,300 people · Purchased surface water · Sampled 2025-07 to 2026-03 · 5 samples at 1 location. Public water system TX0680235, Texas.

EPA test results (UCMR 5)

ChemicalAverage*HighestLevelStatus
PFHxSPerfluorohexanesulfonic acid4.8avg5.4max10 pptEPA 2024 limit, proposed for repealDetected, below level4 of 4 samples
PFBSPerfluorobutanesulfonic acid4.6avg4.9max2,000 pptEPA health-based value (Hazard Index)Detected, below level4 of 4 samples
PFBAPerfluorobutanoic acid12.2avg36.9max7,000 pptUSGS health-based screening levelDetected, below level3 of 4 samples
lithiumLithium34avg37.4max10 µg/LEPA health reference levelAbove screening level4 of 4 samples

26 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.48 (2024 limit 1.0, proposed for repeal).

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Health-based violations since 2016

From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.

No health-based violations recorded in EPA SDWIS since 2016.