PFOA/PFOS average above EPA limit
Columbia City of (SC4010001): PFAS in the water
Serves about 354,068 people · Surface water · Sampled 2024-12 to 2025-09 · 9 samples at 2 locations. Public water system SC4010001, South Carolina.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 5.8avg | 6.9max | 4 pptEPA limit (MCL) | Average above EPA limit6 of 8 samples |
| PFOSPerfluorooctanesulfonic acid | 7.5avg | 8.6max | 4 pptEPA limit (MCL) | Average above EPA limit6 of 8 samples |
| HFPO-DAHFPO-DA (GenX chemicals) | 8.1avg | 9.2max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level5 of 8 samples |
| PFBSPerfluorobutanesulfonic acid | 4.3avg | 5.2max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level4 of 8 samples |
| PFHxAPerfluorohexanoic acid | 4.8avg | 5.7max | 4,000 pptUSGS health-based screening level | Detected, below level8 of 8 samples |
| PFPeAPerfluoropentanoic acid | 5.3avg | 6.8max | No federal level | Detected (no federal level)8 of 8 samples |
| PFHpAPerfluoroheptanoic acid | 0.8avg | 3max | No federal level | Detected (no federal level)1 of 8 samples |
22 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.81 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2024-12-01 Chlorite Stage 1 Disinfectants and Disinfection Byproducts Rule · measured 1.33 MG/L Resolved
- 2021-04-01 Revised Total Coliform Rule Revised Total Coliform Rule Resolved
ZIP codes served
29016 29036 29044 29045 29061 29063 29201 29203 29204 29205 29206 29209 29210 29212 29223 29229