PFOA/PFOS average above EPA limit
Harriman Village: PFAS in the water
Serves about 5,000 people · Groundwater · Sampled 2025-01 to 2025-07 · 4 samples at 2 locations. Public water system NY3503531, New York.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOSPerfluorooctanesulfonic acid | 7.2avg | 7.5max | 4 pptEPA limit (MCL) | Average above EPA limit2 of 4 samples |
| PFHxSPerfluorohexanesulfonic acid | 1.8avg | 3.6max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level1 of 4 samples |
| PFHxAPerfluorohexanoic acid | 3.4avg | 3.7max | 4,000 pptUSGS health-based screening level | Detected, below level2 of 4 samples |
| PFPeAPerfluoropentanoic acid | 5.1avg | 5.7max | No federal level | Detected (no federal level)2 of 4 samples |
| lithiumLithium | 14.9avg | 15.3max | 10 µg/LEPA health reference level | Above screening level2 of 4 samples |
25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.18 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, radium/radionuclide violations are on record, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2017-10-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 22.5 PCI/L Resolved
- 2017-07-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 22.2 PCI/L Resolved
- 2017-04-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 22 PCI/L Resolved
- 2017-01-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 22 PCI/L Resolved
- 2016-07-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 24.9 PCI/L Resolved
- 2016-04-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 24.3 PCI/L Resolved
- 2016-01-01 Combined Uranium Radionuclides and Revised Rad Rule · measured 26.3 PCI/L Resolved