A sample above an EPA limit
South Saint Paul: PFAS in the water
Serves about 20,664 people · Groundwater · Sampled 2024-05 to 2024-11 · 20 samples at 5 locations. Public water system MN1190020, Minnesota.
EPA test results (UCMR 5)
| Chemical | Average* | Highest | Level | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 3.8avg | 7.6max | 4 pptEPA limit (MCL) | One or more samples above1 of 10 samples |
| PFHxSPerfluorohexanesulfonic acid | 2.8avg | 5.6max | 10 pptEPA 2024 limit, proposed for repeal | Detected, below level1 of 10 samples |
| PFBSPerfluorobutanesulfonic acid | 2.4avg | 4.7max | 2,000 pptEPA health-based value (Hazard Index) | Detected, below level1 of 10 samples |
| PFBAPerfluorobutanoic acid | 163avg | 168max | 7,000 pptUSGS health-based screening level | Detected, below level8 of 10 samples |
| PFHxAPerfluorohexanoic acid | 2.4avg | 4.7max | 4,000 pptUSGS health-based screening level | Detected, below level1 of 10 samples |
| PFPeAPerfluoropentanoic acid | 10.3avg | 11max | No federal level | Detected (no federal level)2 of 10 samples |
23 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.
Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.28 (2024 limit 1.0, proposed for repeal).
Filters certified for what was found
Here, PFAS were detected, radium/radionuclide violations are on record. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.
Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters
Health-based violations since 2016
From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.
- 2020-01-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 14 PCI/L Resolved
- 2020-01-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 8.4 PCI/L Resolved
- 2018-10-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 6.5 PCI/L Resolved
- 2018-10-01 Gross Alpha, Excl. Radon and U Radionuclides and Revised Rad Rule · measured 17.2 PCI/L Resolved
- 2018-09-01 Revised Total Coliform Rule Revised Total Coliform Rule Resolved