PFOA/PFOS average above EPA limit

Lake Arrowhead CSD: PFAS in the water

Serves about 7,038 people · Surface water · Sampled 2023-02 to 2024-07 · 11 samples at 2 locations. Public water system CA3610005, California.

EPA test results (UCMR 5)

ChemicalAverage*HighestLevelStatus
PFOAPerfluorooctanoic acid12avg14max4 pptEPA limit (MCL)Average above EPA limit8 of 8 samples
PFOSPerfluorooctanesulfonic acid5.9avg7.2max4 pptEPA limit (MCL)Average above EPA limit8 of 8 samples
PFHxSPerfluorohexanesulfonic acid0.8avg3.3max10 pptEPA 2024 limit, proposed for repealDetected, below level1 of 8 samples
PFNAPerfluorononanoic acid1.1avg4.6max10 pptEPA 2024 limit, proposed for repealDetected, below level1 of 8 samples
PFHxAPerfluorohexanoic acid5.8avg6.7max4,000 pptUSGS health-based screening levelDetected, below level8 of 8 samples
PFPeAPerfluoropentanoic acid4avg4.5maxNo federal levelDetected (no federal level)8 of 8 samples
PFHpAPerfluoroheptanoic acid5.1avg5.7maxNo federal levelDetected (no federal level)8 of 8 samples
PFDAPerfluorodecanoic acid2.6avg3.9maxNo federal levelDetected (no federal level)3 of 8 samples

21 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Hazard Index (PFHxS, PFNA, GenX, PFBS) from location averages: 0.20 (2024 limit 1.0, proposed for repeal).

Filters certified for what was found

Here, PFAS were detected. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Health-based violations since 2016

From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.

No health-based violations recorded in EPA SDWIS since 2016.

ZIP codes served

92317 92321 92352

Where to read more