A sample above an EPA limit

Guntersville Water Works & Sewer Board: PFAS in the water

Serves about 13,374 people · Surface water · Sampled 2023-12 to 2024-09 · 11 samples at 3 locations. Public water system AL0000943, Alabama.

EPA test results (UCMR 5)

ChemicalAverage*HighestLevelStatus
PFOAPerfluorooctanoic acid3.2avg6.8max4 pptEPA limit (MCL)One or more samples above2 of 10 samples
PFOSPerfluorooctanesulfonic acid2.4avg4.8max4 pptEPA limit (MCL)One or more samples above2 of 10 samples
PFBSPerfluorobutanesulfonic acid0.8avg3.3max2,000 pptEPA health-based value (Hazard Index)Detected, below level1 of 10 samples
PFBAPerfluorobutanoic acid8.2avg12max7,000 pptUSGS health-based screening levelDetected, below level8 of 10 samples
PFHxAPerfluorohexanoic acid4.8avg8.7max4,000 pptUSGS health-based screening levelDetected, below level5 of 10 samples
PFPeAPerfluoropentanoic acid3.3avg8.7maxNo federal levelDetected (no federal level)3 of 10 samples
PFHpAPerfluoroheptanoic acid1.9avg3.9maxNo federal levelDetected (no federal level)2 of 10 samples

22 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Filters certified for what was found

Here, PFAS were detected. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Health-based violations since 2016

From EPA SDWIS. "Resolved" or "Archived" means the state closed it out.

No health-based violations recorded in EPA SDWIS since 2016.

ZIP codes served

35976

Where to read more