PFOA/PFOS average above EPA limit

PFAS in Bountiful, UT drinking water

3 public water systems serving ZIP codes in and around Bountiful were tested by EPA for 29 PFAS and lithium. PFAS found in at least one: PFOS, PFHxS, PFBS, PFHxA, PFPeA.

ZIP codes

84010

Water systems

Salt Lake City Water System

Serves about 383,612 people · Surface water · Sampled 2023-10 to 2024-10 · 53 samples at 22 locations · PWS ID UTAH18026

PFOA/PFOS average above EPA limit

ChemicalAverage*HighestLevelStatus
PFOSPerfluorooctanesulfonic acid7.1avg7.1max4 pptEPA limit (MCL)Average above EPA limit1 of 52 samples
PFHxSPerfluorohexanesulfonic acid18.2avg18.2max10 pptEPA 2024 limit, proposed for repealAverage above 2024 limit1 of 52 samples
PFHxAPerfluorohexanoic acid5.7avg5.7max4,000 pptUSGS health-based screening levelDetected, below level1 of 52 samples
PFPeAPerfluoropentanoic acid6.2avg6.2maxNo federal levelDetected (no federal level)1 of 52 samples
lithiumLithium41.7avg42.8max10 µg/LEPA health reference levelAbove screening level25 of 52 samples

25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (1)
  • 2017-09-09 Groundwater Rule Ground Water Rule Resolved
Full report for Salt Lake City Water System →

Bountiful City Water System

Serves about 37,500 people · Surface water · Sampled 2023-01 to 2023-10 · 26 samples at 10 locations · PWS ID UTAH06015

2 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid3.5avg3.7max2,000 pptEPA health-based value (Hazard Index)Detected, below level4 of 25 samples
PFPeAPerfluoropentanoic acid1.5avg3maxNo federal levelDetected (no federal level)1 of 25 samples
lithiumLithium25.2avg26.1max10 µg/LEPA health reference levelAbove screening level16 of 25 samples

27 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (1)
  • 2021-07-01 Combined Radium (-226 and -228) Radionuclides and Revised Rad Rule · measured 9.71 PCI/L Resolved
Full report for Bountiful City Water System →

South Davis Water District

Serves about 10,565 people · Purchased surface water · Sampled 2023-03 to 2023-11 · 14 samples at 5 locations · PWS ID UTAH06009

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFHxSPerfluorohexanesulfonic acid7.5avg12max10 pptEPA 2024 limit, proposed for repealOne or more samples above6 of 10 samples
PFBSPerfluorobutanesulfonic acid1.6avg3.1max2,000 pptEPA health-based value (Hazard Index)Detected, below level1 of 10 samples
PFHxAPerfluorohexanoic acid3.6avg4.6max4,000 pptUSGS health-based screening levelDetected, below level4 of 10 samples
PFPeAPerfluoropentanoic acid4.1avg5.6maxNo federal levelDetected (no federal level)4 of 10 samples
lithiumLithium11.5avg23max10 µg/LEPA health reference levelAbove screening level5 of 10 samples

25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for South Davis Water District →

Filters certified for what was found

Here, PFAS were detected, radium/radionuclide violations are on record, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim. Reverse osmosis also reduces radium, arsenic and nitrate when its listing names them.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters