3 PFAS detected, below EPA limits

PFAS in Windcrest, TX drinking water

3 public water systems serving ZIP codes in and around Windcrest were tested by EPA for 29 PFAS and lithium. PFAS found in at least one: PFBS, PFBA, PFPeA.

ZIP codes

78217 78218 78239

Water systems

San Antonio Water System

Serves about 2,643,729 people · Purchased surface water · Sampled 2023-05 to 2026-06 · 98 samples at 44 locations · PWS ID TX0150018

3 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid3.8avg3.8max2,000 pptEPA health-based value (Hazard Index)Detected, below level2 of 91 samples
PFBAPerfluorobutanoic acid7.6avg9.2max7,000 pptUSGS health-based screening levelDetected, below level3 of 91 samples
PFPeAPerfluoropentanoic acid1.6avg3.2maxNo federal levelDetected (no federal level)1 of 91 samples
lithiumLithium24.3avg25.5max10 µg/LEPA health reference levelAbove screening level38 of 91 samples

26 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for San Antonio Water System →

Bexar County WCID 10 Windcrest

Serves about 8,154 people · Groundwater · Sampled 2024-03 to 2024-11 · 12 samples at 4 locations · PWS ID TX0150106

No PFAS detected

None of the 29 PFAS EPA tested for were found at or above reporting levels and lithium was not detected.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Bexar County WCID 10 Windcrest →

Saws Northeast

Purchased surface water · Sampled 2024-04 to 2025-01 · 11 samples at 5 locations · PWS ID TX0150084

No PFAS detected

ChemicalAverage*HighestLevelStatus
lithiumLithium51.1avg60.3max10 µg/LEPA health reference levelAbove screening level11 of 11 samples

29 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Saws Northeast →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters