A sample above an EPA limit

PFAS in Pharr, TX drinking water

4 public water systems serving ZIP codes in and around Pharr were tested by EPA for 29 PFAS and lithium. PFAS found in at least one: PFOS, PFHxS, PFBS, PFBA, PFHxA, PFPeA, PFHpA.

ZIP codes

78503 78577 78589

Water systems

North Alamo WSC

Serves about 171,195 people · Surface water · Sampled 2023-02 to 2024-02 · 30 samples at 7 locations · PWS ID TX1080029

5 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFHxSPerfluorohexanesulfonic acid0.8avg3.4max10 pptEPA 2024 limit, proposed for repealDetected, below level1 of 26 samples
PFBSPerfluorobutanesulfonic acid0.8avg3max2,000 pptEPA health-based value (Hazard Index)Detected, below level1 of 26 samples
PFBAPerfluorobutanoic acid7avg12.2max7,000 pptUSGS health-based screening levelDetected, below level12 of 26 samples
PFHxAPerfluorohexanoic acid0.9avg3.5max4,000 pptUSGS health-based screening levelDetected, below level2 of 26 samples
PFPeAPerfluoropentanoic acid1.8avg3.8maxNo federal levelDetected (no federal level)2 of 26 samples
lithiumLithium46.2avg50max10 µg/LEPA health reference levelAbove screening level26 of 26 samples

24 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (5)
  • 2025-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .084 MG/L Resolved
  • 2025-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
  • 2018-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
  • 2017-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .09 MG/L Resolved
  • 2017-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .095 MG/L Resolved
Full report for North Alamo WSC →

McAllen Public Utility

Serves about 145,050 people · Surface water · Sampled 2023-06 to 2024-03 · 9 samples at 2 locations · PWS ID TX1080006

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid8.2avg27.2max7,000 pptUSGS health-based screening levelDetected, below level4 of 8 samples
lithiumLithium46avg51.8max10 µg/LEPA health reference levelAbove screening level8 of 8 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for McAllen Public Utility →

City of Pharr

Serves about 79,715 people · Surface water · Sampled 2023-03 to 2023-12 · 4 samples at 1 location · PWS ID TX1080009

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid4.2avg11.2max7,000 pptUSGS health-based screening levelDetected, below level2 of 4 samples
lithiumLithium42.5avg52.9max10 µg/LEPA health reference levelAbove screening level4 of 4 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for City of Pharr →

City of San Juan

Serves about 30,000 people · Surface water · Sampled 2024-11 to 2025-08 · 10 samples at 2 locations · PWS ID TX1080010

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
PFOSPerfluorooctanesulfonic acid1.1avg4.5max4 pptEPA limit (MCL)One or more samples above1 of 8 samples
PFHxSPerfluorohexanesulfonic acid1avg3.9max10 pptEPA 2024 limit, proposed for repealDetected, below level1 of 8 samples
PFBAPerfluorobutanoic acid6.8avg8.2max7,000 pptUSGS health-based screening levelDetected, below level8 of 8 samples
PFHxAPerfluorohexanoic acid5.9avg9max4,000 pptUSGS health-based screening levelDetected, below level8 of 8 samples
PFPeAPerfluoropentanoic acid6.3avg9.2maxNo federal levelDetected (no federal level)8 of 8 samples
PFHpAPerfluoroheptanoic acid0.9avg3.5maxNo federal levelDetected (no federal level)1 of 8 samples
lithiumLithium44.6avg49.8max10 µg/LEPA health reference levelAbove screening level8 of 8 samples

23 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for City of San Juan →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Look for a filter certified to NSF/ANSI 53 or 58 with a PFOA/PFOS claim.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters