2 PFAS detected, below EPA limits

PFAS in Gatesville, TX drinking water

3 public water systems serving ZIP codes in and around Gatesville were tested by EPA for 29 PFAS and lithium. PFAS found in at least one: PFHxS, PFBA, PFHxA, PFPeA.

ZIP codes

76528

Water systems

City of Gatesville

Serves about 16,135 people · Surface water · Sampled 2024-03 to 2025-02 · 5 samples at 1 location · PWS ID TX0500002

2 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFHxSPerfluorohexanesulfonic acid0.8avg3max10 pptEPA 2024 limit, proposed for repealDetected, below level1 of 4 samples
PFBAPerfluorobutanoic acid1.2avg5max7,000 pptUSGS health-based screening levelDetected, below level1 of 4 samples

27 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (1)
  • 2016-02-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Resolved
Full report for City of Gatesville →

Coryell City Water Supply District

Serves about 6,042 people · Purchased surface water · Sampled 2025-01 to 2025-10 · 13 samples at 3 locations · PWS ID TX0500013

1 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid4.4avg6.1max7,000 pptUSGS health-based screening levelDetected, below level7 of 12 samples
lithiumLithium30.7avg61.9max10 µg/LEPA health reference levelAbove screening level4 of 12 samples

28 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (5)
  • 2018-12-21 Revised Total Coliform Rule Revised Total Coliform Rule Resolved
  • 2016-07-01 Total Haloacetic Acids (HAA5) Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .063 MG/L Resolved
  • 2016-04-01 Total Haloacetic Acids (HAA5) Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .061 MG/L Resolved
  • 2016-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .097 MG/L Resolved
  • 2016-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .091 MG/L Resolved
Full report for Coryell City Water Supply District →

Multi-County WSC

Serves about 3,631 people · Purchased surface water · Sampled 2023-03 to 2023-12 · 7 samples at 1 location · PWS ID TX0500044

3 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBAPerfluorobutanoic acid9.9avg15.4max7,000 pptUSGS health-based screening levelDetected, below level3 of 4 samples
PFHxAPerfluorohexanoic acid0.9avg3.8max4,000 pptUSGS health-based screening levelDetected, below level1 of 4 samples
PFPeAPerfluoropentanoic acid1.1avg4.6maxNo federal levelDetected (no federal level)1 of 4 samples

26 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (31)
  • 2026-04-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .094 MG/L Archived
  • 2026-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .093 MG/L Archived
  • 2025-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .089 MG/L Archived
  • 2025-01-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .083 MG/L Resolved
  • 2024-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .096 MG/L Resolved

26 more on the system page.

Full report for Multi-County WSC →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters

Questions

Is Gatesville tap water safe to drink?

PFAS were detected (PFHxS, PFBA) in the City of Gatesville water system, but averages were below EPA's limits. EPA SDWIS lists 37 health-based violations since 2016 for these systems; see each system below. This is monitoring data, not a safety ruling. Your utility's annual Consumer Confidence Report has the full picture.

Are there PFAS in Gatesville water?

Yes. EPA's UCMR 5 tests found PFHxS, PFBA, PFHxA, PFPeA in at least one water system serving Gatesville. Results by system are listed above.

Who supplies drinking water in Gatesville, TX?

The largest tested public water systems serving ZIP codes in and around Gatesville are City of Gatesville (about 16,135 people), Coryell City Water Supply District (about 6,042 people), Multi-County WSC (about 3,631 people). Your address may get water from only one of them; it is named on your water bill.

What filter removes PFAS from Gatesville tap water?

Pick one whose NSF/ANSI 53 or 58 certification names PFOA and PFOS, from NSF, IAPMO R&T, WQA, CSA or UL. Certified pitchers start around $35; under-sink carbon and reverse osmosis systems cost $150 to $700. Reverse osmosis also handles shorter-chain PFAS better. See best water filters for PFAS.

How can I test my own tap water for PFAS?

Lab mail-in kits cost about $85 to $335 or more. See how to test water for PFAS.

More for Gatesville, TX