A sample above an EPA limit

PFAS in Denver, CO drinking water

3 public water systems serving ZIP codes in and around Denver were tested by EPA for 29 PFAS and lithium. PFAS found in at least one: PFBS, PFBA, PFHxA, PFPeA.

ZIP codes

80010 80012 80045 80205 80207 80216 80220 80230 80238 80239

Water systems

Denver Water Board

Serves about 1,287,000 people · Surface water · Sampled 2023-03 to 2025-04 · 18 samples at 4 locations · PWS ID CO0116001

A sample above an EPA limit

ChemicalAverage*HighestLevelStatus
lithiumLithium9.2avg10.8max10 µg/LEPA health reference levelOne or more samples above5 of 15 samples

29 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Denver Water Board →

Aurora City Of

Serves about 533,407 people · Surface water · Sampled 2023-01 to 2024-08 · 13 samples at 3 locations · PWS ID CO0103005

4 PFAS detected, below EPA limits

ChemicalAverage*HighestLevelStatus
PFBSPerfluorobutanesulfonic acid0.8avg3.3max2,000 pptEPA health-based value (Hazard Index)Detected, below level1 of 12 samples
PFBAPerfluorobutanoic acid1.9avg7.8max7,000 pptUSGS health-based screening levelDetected, below level1 of 12 samples
PFHxAPerfluorohexanoic acid1.4avg5.6max4,000 pptUSGS health-based screening levelDetected, below level1 of 12 samples
PFPeAPerfluoropentanoic acid1.8avg7.2maxNo federal levelDetected (no federal level)1 of 12 samples
lithiumLithium17.1avg21.4max10 µg/LEPA health reference levelAbove screening level5 of 12 samples

25 of 29 PFAS tested were not detected. *Highest sampling-location average (non-detects counted as 0), the way EPA compares UCMR 5 data to the PFAS limits. PFAS in parts per trillion (ppt = ng/L); lithium in µg/L.

Health-based violations since 2016 (0)

No health-based violations recorded in EPA SDWIS since 2016.

Full report for Aurora City Of →

Bryan Co. RWS & Swmd #2

Serves about 6,270 people · Surface water · Sampled 2025-01 to 2025-12 · 11 samples at 2 locations · PWS ID OK1010604

No PFAS detected

None of the 29 PFAS EPA tested for were found at or above reporting levels and lithium was not detected.

Health-based violations since 2016 (35)
  • 2026-01-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Archived
  • 2024-01-01 Interim Enhanced Surface Water Treatment Rule Interim and Long Term 1 Enhanced Surface Water Treatment Rule Resolved
  • 2024-01-01 Surface Water Treatment Rule Surface Water Treatment Rule Resolved
  • 2020-10-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .081 MG/L Resolved
  • 2020-07-01 TTHM Stage 2 Disinfectants and Disinfection Byproducts Rule · measured .089 MG/L Resolved

30 more on the system page.

Full report for Bryan Co. RWS & Swmd #2 →

Filters certified for what was found

Here, PFAS were detected, lithium averaged above EPA's screening level. Filter certifications name PFOA and PFOS, which were not detected here. Shorter-chain PFAS like PFBA pass through carbon filters more easily, so reverse osmosis is the more reliable choice.

Certification tests use PFOA/PFOS levels far above tap water and do not yet show reduction down to 4 ppt. Replace cartridges on schedule. Check the model number on the certifier's site (IAPMO, NSF, WQA). As an Amazon Associate we earn from qualifying purchases. How we pick filters